The Lead/Follow control mode allows for one fixture to control many fixtures either wired or wirelessly
Within MANUAL control ONLY, Lead/Follow Mode turns one R2 or RR light into a Lead unit β a wired or wireless Manual Mode controller for any R2 & RR lamps linked as Follow units. Specifically, the Lead unit directly assumes remote color and FX control of its Follow units.
To create dynamic effects across multiple linked units, the Follow feature has selectable slots from 1 to 9. These slots run the same effects, intensities, and levels as the Lead Unit. Follow 1 matches the Lead Unit directly, while Follows 2 through 9 progressively offset effect timings across up to 8 sets of linked units.
To set up Lead/Follow, within the Config Menu, navigate to the Lead/Follow menu and follow these steps:
- In the Lead unit R2/RR lamp youβve chosen to control the Follow units:
- Set this mode to βLeadβ
- The Data status LED will turn Green to confirm your light as the Lead unit
- Any fixtures connected to the Lead unit over DMX will automatically become Follow 1
- In each of your Follow unit R2/RR lamps:
- Set this mode to your desired Follow #:
- Follow 1 matches the Lead Unit in effect timing.
- Follows 2-8 progressively offset effect timing from the lead unit
- Set this mode to your desired Follow #:
With the implementation of auto-follow, setting more than one connected fixture as a Lead unit will result in unexpected behavior and should be avoided
For Wired Linking
- Connect your Lead unit to the first desired Follow unit in the signal chain using a Cat5 or Cat6 cable. One cable end should go in the Lead Unitβs LAN 2/DMX OUT port, and the other end should go in the Follow Unitβs LAN 1/DMX IN port.
- Connect your Follow units together from that first follow unit in similar fashion.
- On the Follow units, the Data status LED will turn Cyan to confirm your light as a Follow unit.
NOTE: When using LEAD/FOLLOW, the lamps should not be receiving DMX data from other sources--unexpected behavior could occur. The Lead Unit should not be receiving outside data and the Lead Unit is distributing the data within the LEAD/FOLLOW system.
For Wireless Linking
- On the Lead unit & all Follow units, navigate to the Wireless Mode config submenu, set to Wireless DMX (CRMX). Bluetooth is disabled in wireless LEAD/FOLLOW.
- If the Wireless status LED flashes on your Follow units, press and hold the Link button to un-pair the Follow unit from searching for a prior Lead Unit.
- On the Lead unit, tap the Link button to send the pairing signal. The Lead unit Wireless Status LED will start flashing. All fixtures paired to a Lead unit will automatically become Follow 1. The Follow unit(s) Wireless Status LED will flash in unison.
- On the Follow units, the Data status LED will turn Cyan to confirm your light as a Follow unit
- The Wireless status LED on ALL Lead & Follow units will turn Magenta to indicate your units are (Lead) transmitting or (Follow) receiving Wireless Lead/Follow Data.
Your Lead unit Manual controls will now directly control all linked Follow Units!
Starting with firmware 0.7, when you set your Leader to control wirelessly, any light it is already paired with will now automatically be set as a Follower.
NOTE: CRMX rules apply with Follow Lamps; if you no longer wish to use a lamp in Follow mode remember to UNLINK the Follow lamp from the Lead lamp; otherwise it will continue to listen to the Lead lampβs CRMX universe broadcast.