Art-Net requires network settings to be correct for proper function

IP addresses of control devices and Quasar Science fixtures must be in the correct ranges for network communication to work correctly.

Menu structure for Wired Settings --> Ethernet Settings:

  • View IP Address - Displays the current IP address assigned to the fixture

  • IP Address Mode

    • Auto - The fixture requests an IP Address from a DHCP server on network. Requires a DHCP server to function correctly.

    • Static - Opens additional sub menus that allow for the following:

      • User assigned IP address Default is 192.168.4.2

      • Subnet mask Default is 255.255.255.0

      • Gateway Default is 192.168.4.1

  • Save DHCP as Static - Stores current IP address to onboard memory

  • Universe - DMX Universe fixture is patched to

  • DMX Channel - DMX Start address fixture is patched to

  • Node Mode - Disabled/Enabled - DMX Out Uni

    • When enabled the LAN 2 Port of the fixture will output DMX

    • When disabled the LAN 2 port of RR fixtures will function as a network switch

    • When disabled the LAN 2 Port of R2 fixtures is disabled

  • DMX Out Universe - DMX Universe output on LAN2 port when Node Mode is enabled